<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>IRANIAN JOURNAL OF ELECTRICAL AND ELECTRONIC ENGINEERING</title>
<title_fa></title_fa>
<short_title>IJEEE</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ijeee.iust.ac.ir</web_url>
<journal_hbi_system_id>18</journal_hbi_system_id>
<journal_hbi_system_user>agent2</journal_hbi_system_user>
<journal_id_issn>1735-2827</journal_id_issn>
<journal_id_issn_online>1735-2827</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Analysis of Partial Discharge Measurements using Coupling Capacitor in Rotating Machine</title>
	<subject_fa>Artificial Intelligence Techniques</subject_fa>
	<subject>Artificial Intelligence Techniques</subject>
	<content_type_fa>Only For Articles of ELECRiS 2024</content_type_fa>
	<content_type>Only For Articles of ELECRiS 2024</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Partial discharge (PD) is a significant concern in the operation of rotating machines such as generators and motors, as it can lead to insulation degradation over time, reducing the reliability and lifespan of the machines. To monitor PD activity, coupling capacitors (CC) are widely used as sensors for online PD detection, as they can effectively capture PD pulses in high-voltage (HV) rotating machines. The primary objective of this research is to measure and analyze PD signals using a CC sensor for HV rotating machines under varying input voltages and frequencies, following the guidelines of the IEC 60270 standard and utilizing the MPD 600 device. The experimental setup includes performing insulation resistance (IR) testing, PD calibration, and PD measurement. Additionally, this paper provides a detailed study of PD signal characteristics, specifically focusing on phase-resolved partial discharge (PRPD) patterns, to understand the behavior of PD in HV rotating machines, enhancing fault diagnosis and preventive maintenance strategies.&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Partial Discharge (PD), Coupling Capacitor (CC), High Voltage Rotating Machine (HVRM), Phase Resolve Partial Discharge (PRPD).</keyword>
	<start_page>233</start_page>
	<end_page>249</end_page>
	<web_url>http://ijeee.iust.ac.ir/browse.php?a_code=A-10-5547-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ahmad Syukri </first_name>
	<middle_name></middle_name>
	<last_name>Abd Rahman</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ahmadsyukri@studentmail.unimap.edu.my</email>
	<code>1800319475328460016556</code>
	<orcid>1800319475328460016556</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MHH Condition Monitoring Sdn Bhd, No.8, Tingkat 1, Jalan Sumazau 1J/KU5, Bandar Bukit Raja, 41050 Klang, Selangor, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mohamad Nur Khairul Hafizi</first_name>
	<middle_name></middle_name>
	<last_name>Rohani</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>khairulhafizi@unimap.edu.my</email>
	<code>1800319475328460016557</code>
	<orcid>1800319475328460016557</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Faculty of Electrical Engineering &amp; Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Nur Dini </first_name>
	<middle_name></middle_name>
	<last_name>Athirah Gazata</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1800319475328460016558</code>
	<orcid>1800319475328460016558</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering &amp; Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Afifah Shuhada </first_name>
	<middle_name></middle_name>
	<last_name>Rosmi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>afifahshuhada@unimap.edu.my</email>
	<code>1800319475328460016559</code>
	<orcid>1800319475328460016559</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering &amp; Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Ayob </first_name>
	<middle_name></middle_name>
	<last_name>Nazmi Nanyan</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ayobnazmy@unimap.edu.my</email>
	<code>1800319475328460016560</code>
	<orcid>1800319475328460016560</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering &amp; Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Aiman Ismail </first_name>
	<middle_name></middle_name>
	<last_name>Mohamed Jamil</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aimanismail@studentmail.unimap.edu.my</email>
	<code>1800319475328460016561</code>
	<orcid>1800319475328460016561</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of Electrical Engineering &amp; Technology, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mohd Helmy </first_name>
	<middle_name></middle_name>
	<last_name>Halim Abdul Majid</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>helmy.uitm@mhhlegacy.com.my</email>
	<code>1800319475328460016562</code>
	<orcid>1800319475328460016562</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MHH Condition Monitoring Sdn Bhd, No.8, Tingkat 1, Jalan Sumazau 1J/KU5, Bandar Bukit Raja, 41050 Klang, Selangor, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Normiza Masturina </first_name>
	<middle_name></middle_name>
	<last_name>Samsuddin</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>normiza@mhhlegacy.com.my</email>
	<code>1800319475328460016563</code>
	<orcid>1800319475328460016563</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MHH Condition Monitoring Sdn Bhd, No.8, Tingkat 1, Jalan Sumazau 1J/KU5, Bandar Bukit Raja, 41050 Klang, Selangor, Malaysia.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
