<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>IRANIAN JOURNAL OF ELECTRICAL AND ELECTRONIC ENGINEERING</title>
<title_fa></title_fa>
<short_title>IJEEE</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ijeee.iust.ac.ir</web_url>
<journal_hbi_system_id>18</journal_hbi_system_id>
<journal_hbi_system_user>agent2</journal_hbi_system_user>
<journal_id_issn>1735-2827</journal_id_issn>
<journal_id_issn_online>1735-2827</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Design of a Permanent-Magnet Synchronous Generator for a 2 MW Gearless Horizontal-Axis Wind Turbine According to its Capability Curves</title>
	<subject_fa>Electrical Machines Design-1</subject_fa>
	<subject>Electrical Machines Design</subject>
	<content_type_fa>Research Paper </content_type_fa>
	<content_type>Research Paper </content_type>
	<abstract_fa></abstract_fa>
	<abstract>Permanent-Magnet Synchronous Generators (PMSGs) exhibit high efficiency and power density, and have already been employed in gearless wind turbines. In the gearless wind turbines, due to the removal of the gearbox, the cogging torque is an important issue. Therefore, in this paper, at first, design of a Permanent-Magnet Synchronous Generator for a 2MW gearless horizontal-axis wind turbine, according to torque-speed and capability curves, is presented. For estimation of cogging torque in PMSGs, an analytical method is used. Performance and accuracy of this method is compared with the results of Finite Element Method (FEM). Considering the effect of dominant design parameters, cogging torque is efficiently reduced.</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Permanent-Magnet Synchronous Generator,Power Coefficient,Magnetic Voltage,Cogging Torque,</keyword>
	<start_page>52</start_page>
	<end_page>60</end_page>
	<web_url>http://ijeee.iust.ac.ir/browse.php?a_code=A-10-1176-2&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Darijani</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ahaddarijani@gmail.com</email>
	<code>180031947532846003252</code>
	<orcid>180031947532846003252</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Kiyoumarsi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kiyoumarsi@eng.ui.ac.ir</email>
	<code>180031947532846003253</code>
	<orcid>180031947532846003253</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H. A.</first_name>
	<middle_name></middle_name>
	<last_name>Lari</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>heidar.ali.lari@gmali.com</email>
	<code>180031947532846003254</code>
	<orcid>180031947532846003254</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>B.</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaeian Dehkordi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mirzaeian@eng.ui.ac.ir</email>
	<code>180031947532846003255</code>
	<orcid>180031947532846003255</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Sh.</first_name>
	<middle_name></middle_name>
	<last_name>Bekhrad</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shbekhrad@yahoo.com</email>
	<code>180031947532846003256</code>
	<orcid>180031947532846003256</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S.</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi Monjezi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>180031947532846003257</code>
	<orcid>180031947532846003257</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Department of Electrical Engineering, Faculty of Engineering, University of Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
