<?xml version="1.0" encoding="utf-8"?>
 <ArticleSet>
	
		<Article>
		<Journal>
			<PublisherName>Iran University of Science and Technology (IUST)</PublisherName>
			<JournalTitle>Iranian Journal of Electrical and Electronic Engineering</JournalTitle>
			<PISSN>1735-2827</PISSN>
			<EISSN>1735-2827</EISSN>
			<Volume>3</Volume>
			<Issue>3</Issue>
			<PubDate PubStatus="epublish">
				<Year>2007</Year>
				<Month>7</Month>
				<Day>1</Day>
			</PubDate>
		</Journal>
			
		<ArticleTitle>Error Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer</ArticleTitle>
		<FirstPage>53</FirstPage>
		<LastPage>63</LastPage>
		<Language>EN</Language>
		

	<AuthorList>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>S. Olyaee</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>Sh. Mohammad-Nejad</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>Y</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	</AuthorList>
	<DOI></DOI>
	<Abstract>A new heterodyne nano-displacement with error reduction is presented. The
main errors affecting the displacement accuracy of the nano-displacement measurement
system including intermodulation distortion error, cross-talk error, cross-polarization error
and phase detection error are calculated. In the designed system, a He-Ne laser having
three-longitudinal-mode is considered as the stabilized source. The free spectral range of
the 35cm laser cavity is about 435-MHz at 632.8-nm wavelength, which a secondary beat
frequency equal to 300-kHz is produced by combining the reference and measurement
beams. The resolution of the displacement measurement resulting from intermodulation
distortion, cross-talk and cross-polarization errors is limited to 18-pm. Also, the phase
detection uncertainty causes an error of only 5.9-pm in the displacement measurement.
Furthermore, frequency-path models of two- and three-longitudinal-mode laser
interferometers are modeled as the ac interference, ac reference, dc interference and optical
power terms. A comparison study between two- and three-longitudinal-mode laser
interferometers confirms that the performance of the designed system is considerably
improved.</Abstract>
	<Keywords>Cross-Polarization,Frequency-Path Model,He-Ne Laser,Heterodyne Interferometry,Intermodulation Distortion,Nano-Displacement,</Keywords>

			<URLs>
				<abstract>http://ijeee.iust.ac.ir/article-1-27-en.html</abstract>
				<Fulltext>
					<pdf>http://ijeee.iust.ac.ir/article-1-27-en.pdf</pdf>
				</Fulltext>
			</URLs>
			
			
	</Article>
	
		<Article>
		<Journal>
			<PublisherName>Iran University of Science and Technology (IUST)</PublisherName>
			<JournalTitle>Iranian Journal of Electrical and Electronic Engineering</JournalTitle>
			<PISSN>1735-2827</PISSN>
			<EISSN>1735-2827</EISSN>
			<Volume>3</Volume>
			<Issue>3</Issue>
			<PubDate PubStatus="epublish">
				<Year>2007</Year>
				<Month>7</Month>
				<Day>1</Day>
			</PubDate>
		</Journal>
			
		<ArticleTitle>Broadband Stacked Microstrip Patch Antenna for L-Band Operation: FDTD Modeling</ArticleTitle>
		<FirstPage>64</FirstPage>
		<LastPage>71</LastPage>
		<Language>EN</Language>
		

	<AuthorList>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>A. Hajiaboli</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>Y</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>Hodjat-Kashani</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>M. Omidi</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	</AuthorList>
	<DOI></DOI>
	<Abstract>This paper presents a novel implementation of an electromagnetically coupled
patch antenna using air gap filled substrates to achieve the maximum bandwidth. We also
propose an efficient modeling technique using the FDTD method which can substantially
reduce the simulation cost for modeling the structure. The simulated results have been
compared with measurement to show the broadband behavior of the antenna and the
accuracy of the proposed modeling technique. The measured results show a 16% of
VSWR&#60;2 bandwidth which is considerable considering the inherent bandwidth limitations
in microstrip antenna technology.</Abstract>
	<Keywords>Broad Bandwidth,EMCP,FDTD Methods,Microstrip Antenna,Sub-Cell Modeling,</Keywords>

			<URLs>
				<abstract>http://ijeee.iust.ac.ir/article-1-28-en.html</abstract>
				<Fulltext>
					<pdf>http://ijeee.iust.ac.ir/article-1-28-en.pdf</pdf>
				</Fulltext>
			</URLs>
			
			
	</Article>
	
		<Article>
		<Journal>
			<PublisherName>Iran University of Science and Technology (IUST)</PublisherName>
			<JournalTitle>Iranian Journal of Electrical and Electronic Engineering</JournalTitle>
			<PISSN>1735-2827</PISSN>
			<EISSN>1735-2827</EISSN>
			<Volume>3</Volume>
			<Issue>3</Issue>
			<PubDate PubStatus="epublish">
				<Year>2007</Year>
				<Month>7</Month>
				<Day>1</Day>
			</PubDate>
		</Journal>
			
		<ArticleTitle>Stator Fault Detection in Induction Machines by Parameter Estimation Using Adaptive Kalman Filter</ArticleTitle>
		<FirstPage>72</FirstPage>
		<LastPage>82</LastPage>
		<Language>EN</Language>
		

	<AuthorList>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>F. Bagheri</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>H. Khaloozadeh</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>Y</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>K. Abbaszadeh</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	</AuthorList>
	<DOI></DOI>
	<Abstract>This paper presents a parametric low differential order model, suitable for
mathematically analysis for Induction Machines with faulty stator. An adaptive Kalman
filter is proposed for recursively estimating the states and parameters of continuous–time
model with discrete measurements for fault detection ends. Typical motor faults as interturn
short circuit and increased winding resistance are taken into account. The models are
validated against winding function induction motor modeling which is well known in
machine modeling field. The validation shows very good agreement between proposed
method simulations and winding function method, for short-turn stator fault detection.</Abstract>
	<Keywords>Adaptive Kalman Filter,Fault Detection,Induction Machine,Parameter Estimation,Stator Faults,</Keywords>

			<URLs>
				<abstract>http://ijeee.iust.ac.ir/article-1-29-en.html</abstract>
				<Fulltext>
					<pdf>http://ijeee.iust.ac.ir/article-1-29-en.pdf</pdf>
				</Fulltext>
			</URLs>
			
			
	</Article>
	
		<Article>
		<Journal>
			<PublisherName>Iran University of Science and Technology (IUST)</PublisherName>
			<JournalTitle>Iranian Journal of Electrical and Electronic Engineering</JournalTitle>
			<PISSN>1735-2827</PISSN>
			<EISSN>1735-2827</EISSN>
			<Volume>3</Volume>
			<Issue>3</Issue>
			<PubDate PubStatus="epublish">
				<Year>2007</Year>
				<Month>7</Month>
				<Day>1</Day>
			</PubDate>
		</Journal>
			
		<ArticleTitle>A Novel Method for Commutation Torque Ripple Reduction of Four-Switch, Three-Phase Brushless DC Motor Drive</ArticleTitle>
		<FirstPage>83</FirstPage>
		<LastPage>97</LastPage>
		<Language>EN</Language>
		

	<AuthorList>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>A. Halvaei-Niasar</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>A. Vahedi</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>Y</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>H. Moghbelli</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	</AuthorList>
	<DOI></DOI>
	<Abstract>This paper presents an original study on the generated torque ripples of phase
commutation in the Four-Switch, Three-Phase Inverter (FSTPI) Brushless DC (BLDC)
motor drive which is suitable for low cost applications. Analytic values of torque ripple and
commutation duration are obtained for different operation conditions. Moreover, limitation
on the speed range operation caused from splitting of the DC-link voltage is shown exactly.
Then a novel current control technique is developed to minimize the commutation torque
ripple for a wide speed range. The technique proposed here is based on a strategy that the
current slopes of the rising and the decaying phases during the commutation intervals can
be equalized by proper duty-ratios at commutations. Finally, the validity of the proposed
analysis and developed torque ripple reduction technique are verified via simulation.</Abstract>
	<Keywords>Brushless DC Motor,Commutation Torque Ripple,Four-Switch Inverter,</Keywords>

			<URLs>
				<abstract>http://ijeee.iust.ac.ir/article-1-30-en.html</abstract>
				<Fulltext>
					<pdf>http://ijeee.iust.ac.ir/article-1-30-en.pdf</pdf>
				</Fulltext>
			</URLs>
			
			
	</Article>
	
		<Article>
		<Journal>
			<PublisherName>Iran University of Science and Technology (IUST)</PublisherName>
			<JournalTitle>Iranian Journal of Electrical and Electronic Engineering</JournalTitle>
			<PISSN>1735-2827</PISSN>
			<EISSN>1735-2827</EISSN>
			<Volume>3</Volume>
			<Issue>3</Issue>
			<PubDate PubStatus="epublish">
				<Year>2007</Year>
				<Month>7</Month>
				<Day>1</Day>
			</PubDate>
		</Journal>
			
		<ArticleTitle>Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads</ArticleTitle>
		<FirstPage>98</FirstPage>
		<LastPage>115</LastPage>
		<Language>EN</Language>
		

	<AuthorList>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>R. Noroozian</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>Y</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>M. Abedi</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>G. B. Gharehpetian</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	<Author>
	<FirstName></FirstName>
	<MiddleName></MiddleName>
	<LastName>S. H. Hosseini</LastName>
	<Affiliation></Affiliation>
	<AuthorEmails></AuthorEmails>
	<CorrespondingAuthor>N</CorrespondingAuthor>
	<ORCID></ORCID>
	 </Author>
	</AuthorList>
	<DOI></DOI>
	<Abstract>This paper describes a DC isolated network which is fed with Distributed
Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC
loads. The battery energy storage bank has been connected to the DC network via DC/DC
converter to control the voltage of the network and optimize the operation of the PV
generation units. The PV arrays are connected to the DC network via its own DC/DC
converter to ensure the required power flow. The unbalanced AC loads are connected to the
DC network via its own DC/AC converter. This paper proposes a novel control strategy for
storage converter which has a DC voltage droop regulator. Also a novel control system
based on Park rotating frame has been proposed for DC/AC converters. In this paper, the
proposed operation method is demonstrated by simulation of power transfer between PV
arrays, unbalanced AC loads and battery unit. The simulation results based on
PSCAD/EMTDC software show that DC isolated distribution system including PV
generation systems can provide the high power quality to supplying unbalanced AC loads.</Abstract>
	<Keywords>Distributed Generation,Photovoltaic,Power Control,Power Quality,Stand Alone System,Strategy Control,</Keywords>

			<URLs>
				<abstract>http://ijeee.iust.ac.ir/article-1-31-en.html</abstract>
				<Fulltext>
					<pdf>http://ijeee.iust.ac.ir/article-1-31-en.pdf</pdf>
				</Fulltext>
			</URLs>
			
			
	</Article>